Constance
610 series portable gas detector: it can detect one kind of gas (showed in
form). It is intrinsically safe instrument that can continuously detect the
concentration of combustible gas and toxic gas. Constance 610 Gas detector
is designed for safety technical personnel and equipment maintenance personnel
to guarantee the staff's life safety and to protect production equipment from
losses.
Constance
610 Gas detector detects gas concentration in natural diffusion way, and also
can use external suction pump to sample gas. This gas detector normally use
imported electrochemical sensor (use catalytic combustion sensor for
combustible gas detector). It has excellent sensitivity and good repeatability.
Constance
610 Gas detector is easy to
take,waterproof, dustproof and explosion-proof
l Big
OLED display, Highlighted, High-definition
l
Automatically save the detecting data for 5000 records
l Data
progress bar display mode, can learn about the state of concentration
l Low
power consumption , save energy, save electricity
l
Real-time clock display function
l The key
operation needs to input password to prevent wrong operation.
l Automatic
calibration function, reduce the measuring error.
l Recover
key data, avoid the loss of data
l Battery
power real-time display, under-voltage hint, low pressure automatic shutdown
l
Standard MINI-USB charging interface; charger is compatible with computer and
cell phone's
l
Charging protection function; when battery is full, charger will shut down
automatically.
l
Computer connection function; to realize data download, parameter setting
(optional)
l Alarm
type: audible and visual alarm, vibrating alarm
l STEL
and TWA alarm function for toxic gases
l Power
on self-test function
l Adjustable high and low
alarm level
Detecting Gas |
Combustible gas, Toxic gas, Oxygen |
Measuring Range |
see the chart |
Sampling Method |
diffused or pump suction (external electric sampling pump) |
Deviation |
≤± 3% F.S |
Respond Time |
T90 < 30 s |
Working Temperature |
toxic gas: - 20 ℃ ~ + 50 ℃ |
Working Humidity |
< 95% R.H. no condensation |
Sensor life |
see the chart |
Display Mode |
OLED screen shows density, time, battery power, Alarm state, |
Data Storage |
5000 records |
Upload Data |
connected to computer via data line(optional) |
Alarm Type |
Light: wide-angle light emitting diode |
Working Voltage |
DC3.6 V lithium ion battery, 1000 mAh |
Charging Time |
4 h ~ 6 h |
Working Time |
combustible gas ≮ 8 h (continuous); Toxic gas ≮ 72 h (continuous) |
Protection Class |
IP66 |
Weight |
140 g |
Appearance Size |
98 mm × 60 mm × 24 mm |
instrument
box, gas detector, specifications, certificate of approval, warranty card,
charger, gas hood
widely
used in Metallurgy, petrochemical industry, coal mine, papermaking,
fire-fighting, municipal affairs, pharmacy, power plant, chemical industry,
mine, tunnel, underground pipeline, etc.
Product Model |
Detected Gas |
Measuring Range |
Resolution |
Respond |
Sensor life |
610-EX |
Combustible gas |
0-100%LEL |
1%LEL |
≤30 s |
3-5 year |
610-CO |
CO |
0-1000ppm |
1ppm |
≤20 s |
2-3 year |
610-O2 |
O2 |
0-30%VOL |
0.1%vol |
≤20 s |
2-3 year |
610-O3 |
O3 |
0-5ppm 0-100ppm |
0.1ppm 1ppm |
≤30s |
2-3 year |
610-H2S |
H2S |
0-100ppm |
1ppm |
≤30 s |
2-3 year |
610-H2 |
H2 |
0-1000ppm |
1ppm |
≤30 s |
2-3 year |
610-CL2 |
CL2 |
0-20ppm |
0.1ppm |
≤30 s |
2-3 year |
PG610-NH3 |
NH3 |
0-200ppm |
1ppm |
≤30 s |
2-3 year |
610-SO2 |
SO2 |
0-20ppm |
0.1ppm |
≤30 s |
2-3 year |
610-NO |
NO |
0-250ppm |
1ppm |
≤30 s |
2-3 year |
610-NO2 |
NO2 |
0-20ppm |
0.1ppm |
≤30 s |
2-3 year |
610-CH2O |
CH2O |
0-50ppm |
0.01ppm |
≤30 s |
2-3 year |
610-HCL |
HCL |
0-20ppm |
0.1ppm |
≤30 s |
2-3 year |
610-HCN |
HCN |
0-20ppm |
0.1ppm |
≤30 s |
2-3 year |
610-ETO |
ETO |
0-100ppm |
1ppm |
≤30 s |
2-3 year |
610-CLO2 |
CLO2 |
0-10ppm |
0.1ppm |
≤30 s |
2-3 year |
610-CO2 |
CO2 |
0-5.00%vol 0-5000ppm |
0.01%vol 1ppm |
≤30 s |
5-10 year |
610-VOC |
VOC |
0-50ppm |
≤30 s |