Sample/Reagent tray
·120 sample position
·90 reagent position
·Reagent refrigerated function
Reaction tray
·90 reusable cuvettes
·Automatic blank testing for cuvettes
·Colorimetry system of the pattern of light splitting behind cuvettes
·Dismountable, easily replacement
·Reaction temperature 37℃,constant temperature function
Sample/Reagent Probe
·Automatic liquid level detecting
·Collision protection function
·Probe internal/external washing
·Probe deepth automatic adjustment
Auto cleaning system
·Automatically 6-step wash
·2 times repeat wash
·Hi-tech washing station to ensure
accurate results
Auto mixer, independently
·Automatically mix reagent and sample in cuvettes
·Ensure full reaction
·Automated wash itself
·Avoid cross-contamination
Perfect standard diagram
·Automatic show reaction curve
·QC result diagram recorder,print available
Intelligent software
·Automatic washing cuvette when start test&finish test
·Automatic detect sample& reagent volume
·Reaction temperature detecting when startup
·Alarm: automatic alarm of no reagent,no sample,wrong run,out of linearity range etc
·Automatic re-test sample in next order if no reagent
Real-time and Dynamic display running status
·Real-time show the running status
·Real-time show the status of reagent tray,sample tray,cuvettes
·Real-time update the reagent residual volume
Overall Performance | Model | BK-480(RUBY) |
Type | Vertical,Discrete,Fully automatic | |
Throughput | 400T/H | |
Analysis Method | End-point,kinetic,Two-point | |
Certification | CE, FDA, ISO9001, ISO14001, ISO13485 | |
Sample & Reagent Unit | Sample Positions | 120 sample positions |
Reagent Positions | 90 pcs (With refrigerated function) | |
Sample Volume | 2-30ul,0.1μl step | |
Reagent Volume | 20-300μl,1μl step | |
Sample& Reagent Probe | Automatic liquid level detecting Collision protection function Probe internal/external washing Probe deepth automatic adjustmen | |
Probe cleaning | Automatic washing both interior and exterior | |
Reagent tray cooling | Continuous 2℃~8℃ cooling within 24 hours | |
Reaction Unit | Reaction Time | 10 minutes |
Temperature Control | 37±0.1℃,automatic heating | |
Cuvettes | 90 reusable reaction cuvettes | |
Washing | After finishtesting, washing probe wash cuvettes automatically | |
Optical System | Light Source | Halogen-tungsten lamp |
Wavelength | 340-700nm,8 wavelengths,(4 positions are optional) | |
Absorbance range | 0-4.00Abs | |
Linear Range | 0.0001Abs | |
Calibration and QC | Calibration | Linear/nonlinear,one point,multi-point(Max 8 points) |
Quality Control | QC plot automatically depict the function condition,show the QC results | |
Software | Intelligent software | Automatic washing cuvette when start test&finish test,Automatic detect sample& reagent volume,Reaction temperature detecting when startup |
Alarm | Automatic alarm of no reagent,no sample,wrong run,out of linearity range etc, Automatic re-test sample in next order after no reagent | |
Software | Windows 7,Windows 8 or above, windows XP | |
Others | Power Supply | AC110/220V,±10%, 50/60Hz,1000VA |
Package Size(W*D*H) | 1220*1340*890mm | |
Gross Weight | 200kg |