BK-500(DIAMOND) AUTO CHEMISTRY ANALYZER

BK-500(DIAMOND) AUTO CHEMISTRY ANALYZER

Features:

①. 90 Sample positions.        

②. 120 Reaction cuvettes (reusable).  

③. 90 Refrigerated reagent positions (R1:45 & R2:45).            

④. Auto 7-step washing system.

⑤. 550 tests per hour with STAT function.

⑥. One sample probe, two reagent probes, Anti-collision function.

⑦. Liquid level detection function, real-time display reagent volume.



Reaction tray
37°C±0.1°C, real-time monitor.


Reagent tray

2°C~8°C cooling for 24 hours.


Stirring needle

Teflon coating to avoid cross contamination



Sample needle

Liquid level sensor function. Anti-collision function. Reagent volume real-time detection.



Software

User-friendly software



Washing Probe

Independent 7-step washing system.


Overall

Performance

Model

 BK-500(DIAMOND)

Type

Random, Discrete, fully automatic

Test Speed

550Tests/Hour

Analysis Method

End-point, Fixed-time, Rate, Two-points, Turbidimetry

Certificates

CE, FDA, ISO9001, ISO14001, ISO13485

 

Sample unit

Sample Settings

 90 sample positions, including calibration, quality control and emergency

Sample Volume

 2ul ~70ul (0.1ul stepping)

Sample Probe

 Liquid level detection function

Probe Washing

 Automatically wash interior and exterior

Analysis Items

 Analyzing maximally 45 items at the same time

 

Reagent unit

Reagent Position

 R1: 45, R2: 45, total 90 refrigerated reagent positions

Reagent Volume

 20~350μl (1μl stepping)

Temperature Control

 2°C~8°C cooling for 24 hours

Reagent Probe

 Liquid level sensor function

Probe cleaning

 Automatically wash interior and exterior

Reaction unit

Temperature

 37°C±0.1°C, real-time monitor

Cuvettes

120 reusable reaction cuvettes (optical path length 6mm)

Mixer Probe

 After adding reagent and sample, mix immediately

Washing

 Automatically cuvettes washing

System adjustment

System can record the blank value and get more,

accurate results by deducting blank base value of each cuvette

Optical System

Light Source

 12V/30W halogen-tungsten lamp, 2000 hours lifetime

Receiver

 8 precision photo receivers

Wavelength Range

 340, 405, 450, 510, 546, 578, 630, 700mm

Linear Range

 0.000~3.000Abs

Calibration and QC

Calibration

 One-point, two-point, multi-point, factor, logit-4P, logit-5P, spline

Quality Control

Inserting quality control at random

 

Software

STAT Function

 Emergency samples can be placed in the sample tray at any time

Computer System

 Windows 7/8/10, LIS system available

Data Processing

 Reaction curve and data display function

Others

Power Supply

 AC110/220V±10%, 60/50Hz

Consumption

 750w

Package Size(W*D*H)

 1348*928*1399mm(Machine)      678*624*548mm(Accessories)

Gross weight

 360kg